The crucial multi-physics problem of how to extrapolate from the performance of an isolated Nb3Sn strand measured in the laboratory to the performance of a superconducting coil using multi-strand twisted cables is addressed here. We consider the particular case of the path going from the LMI strand to the international thermonuclear experimental reactor (ITER) toroidal field model coil (TFMC), through its associated Full Size Joint Sample, the TFMC-FSJS. Mechanical, electromagnetic and thermal–hydraulic conditions are simulated using the ANSYS, ENSIC and Mithrandir/M&M codes, respectively. At least in this case, the DC performance of the short sample turns out to be relatively close to (considering error bars) but not fully representative of that of the coil, showing higher (less compressive) effective thermal strain but also higher sensitivity to the electromechanical load.

Coupled mechanical–electromagnetic–thermal–hydraulic effects in Nb3Sncable-in-conduit conductors for ITER / Zanino, Roberto; Ciazynski, D.; Mitchell, N.; Savoldi, Laura. - In: SUPERCONDUCTOR SCIENCE & TECHNOLOGY. - ISSN 0953-2048. - 18:(2005), pp. S376-S382.

Coupled mechanical–electromagnetic–thermal–hydraulic effects in Nb3Sncable-in-conduit conductors for ITER

ZANINO, Roberto;SAVOLDI, LAURA
2005

Abstract

The crucial multi-physics problem of how to extrapolate from the performance of an isolated Nb3Sn strand measured in the laboratory to the performance of a superconducting coil using multi-strand twisted cables is addressed here. We consider the particular case of the path going from the LMI strand to the international thermonuclear experimental reactor (ITER) toroidal field model coil (TFMC), through its associated Full Size Joint Sample, the TFMC-FSJS. Mechanical, electromagnetic and thermal–hydraulic conditions are simulated using the ANSYS, ENSIC and Mithrandir/M&M codes, respectively. At least in this case, the DC performance of the short sample turns out to be relatively close to (considering error bars) but not fully representative of that of the coil, showing higher (less compressive) effective thermal strain but also higher sensitivity to the electromechanical load.
2005
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/1407312
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo