A general model of electric heating loads regulated by automatically-controlled thermostats is presented. The model is based on the equations of the thermal transients due to the thermostat operation. The power/voltage characteristic of a single load is obtained from the static analysis, showing its dependence on the most significant parameters of the thermostatic control, and the transient behaviour due to a step supply voltage decrease. The dynamic analysis is performed by simulating the response of a community of thermostatically-controlled loads with random initial conditions, subjected to step voltage variations. A theoretical justification of the behaviour of an aggregation of equal loads is given. Simulations are carried out to show the power response to voltage drops of different depth, up to the extreme situation of a load pick up which follows a temporary outage

Analysis and modelling of thermostatically-controlled loads / Bompard, Ettore Francesco; Carpaneto, Enrico; Chicco, Gianfranco; Napoli, Roberto. - 2:(1996), pp. 730-734. (Intervento presentato al convegno IEEE MELECON‘96, 8th Mediterranean Electrotechnical Conference tenutosi a Bari, Italy nel May 13-16, 1996) [10.1109/MELCON.1996.551321].

Analysis and modelling of thermostatically-controlled loads

BOMPARD, Ettore Francesco;CARPANETO, Enrico;CHICCO, GIANFRANCO;NAPOLI, Roberto
1996

Abstract

A general model of electric heating loads regulated by automatically-controlled thermostats is presented. The model is based on the equations of the thermal transients due to the thermostat operation. The power/voltage characteristic of a single load is obtained from the static analysis, showing its dependence on the most significant parameters of the thermostatic control, and the transient behaviour due to a step supply voltage decrease. The dynamic analysis is performed by simulating the response of a community of thermostatically-controlled loads with random initial conditions, subjected to step voltage variations. A theoretical justification of the behaviour of an aggregation of equal loads is given. Simulations are carried out to show the power response to voltage drops of different depth, up to the extreme situation of a load pick up which follows a temporary outage
1996
0780331095
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/1408618
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo