Dynamic infrared imaging is a promising technique to be applied to early breast cancer diagnosis. It is based on the acquisition of hundreds of consecutive thermal images with a frame rate ranging from 50 to 200 frames/s, followed by the spectral analysis of temperature time series at each image pixel. To improve the time series signal-to-noise ratio, it is useful to realign the thermal images of the acquisition sequence. Our previous studies demonstrated that a registration algorithm based on fiducial points is suitable to both clinical applications and research, when associated with a proper set of skin markers. In this paper, we evaluate the performance of different marker sets by means of a model that allows estimating the signal-to-noise ratio increment due to registration, and we conclude that a 9-marker set is a good compromise between motion artifact reduction and the time required to prepare the patient.

Evaluation of different marker sets for motion artifact reduction in breast Dynamic Infrared Imaging / Agostini, Valentina; Knaflitz, Marco; Molinari, Filippo. - (2007), pp. 3377-3379. (Intervento presentato al convegno 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBS) tenutosi a Lione nel 23-26 agosto 2007) [10.1109/IEMBS.2007.4353055].

Evaluation of different marker sets for motion artifact reduction in breast Dynamic Infrared Imaging

AGOSTINI, VALENTINA;KNAFLITZ, Marco;MOLINARI, FILIPPO
2007

Abstract

Dynamic infrared imaging is a promising technique to be applied to early breast cancer diagnosis. It is based on the acquisition of hundreds of consecutive thermal images with a frame rate ranging from 50 to 200 frames/s, followed by the spectral analysis of temperature time series at each image pixel. To improve the time series signal-to-noise ratio, it is useful to realign the thermal images of the acquisition sequence. Our previous studies demonstrated that a registration algorithm based on fiducial points is suitable to both clinical applications and research, when associated with a proper set of skin markers. In this paper, we evaluate the performance of different marker sets by means of a model that allows estimating the signal-to-noise ratio increment due to registration, and we conclude that a 9-marker set is a good compromise between motion artifact reduction and the time required to prepare the patient.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/1730565
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo