This paper reports the main results of a parametric analysis which was performed to define appropriate limits of the span-to-height ratio of p.c. beams or slabs that are in compliance with the deflection control required by international standards (Eurocode 2, Model Code 1990) for concrete buildings structures. Two deflections were considered: the total deflection and the active deflection that occurs after construction, in both cases under the quasi-permanent load combination. The active deflection has to be considered when fragile elements such as partitions or glazing are present on the structure. Four structural systems were considered: simply supported fully or partially prestressed beams with a I-section and simply supported or fixed end slabs with a rectangular cross section. The load history first included the application of the prestress and the dead load and then the application of the remaining quasi-permanent load. Taking into account the effects of imposed deformations the structure was designed to obtain the geometrical properties strictly necessary for the ultimate limit state (ULS) and for stress limitation in service under quasi-permanent and characteristic load combinations. The results allow the influence of some of the variables that most affect the deflection to be evaluated, such as the span and the height of the beams, the concrete strength, the permanent load and the variable-to-permanent load ratio.

Span-to-height ratio limits for prestressed concrete members / Debernardi, PIER GIORGIO; Taliano, Maurizio. - In: STRUCTURAL CONCRETE. - ISSN 1464-4177. - STAMPA. - 11:(2010), pp. 35-43.

Span-to-height ratio limits for prestressed concrete members

DEBERNARDI, PIER GIORGIO;TALIANO, Maurizio
2010

Abstract

This paper reports the main results of a parametric analysis which was performed to define appropriate limits of the span-to-height ratio of p.c. beams or slabs that are in compliance with the deflection control required by international standards (Eurocode 2, Model Code 1990) for concrete buildings structures. Two deflections were considered: the total deflection and the active deflection that occurs after construction, in both cases under the quasi-permanent load combination. The active deflection has to be considered when fragile elements such as partitions or glazing are present on the structure. Four structural systems were considered: simply supported fully or partially prestressed beams with a I-section and simply supported or fixed end slabs with a rectangular cross section. The load history first included the application of the prestress and the dead load and then the application of the remaining quasi-permanent load. Taking into account the effects of imposed deformations the structure was designed to obtain the geometrical properties strictly necessary for the ultimate limit state (ULS) and for stress limitation in service under quasi-permanent and characteristic load combinations. The results allow the influence of some of the variables that most affect the deflection to be evaluated, such as the span and the height of the beams, the concrete strength, the permanent load and the variable-to-permanent load ratio.
2010
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2372586
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo