In the last 10 years, the number of field applications of zero-valent iron differing from permeable reactive barrier has grown rapidly and at present are 112. This study analyzes and compares such field applications. By using statistical analysis, especially ANO VA and principal component analysis, this study shows that chlorinated solvent contamination can be treated efficiently by using zero-valent iron material singly or associated with other technologies. In the analyzed sample of case studies, the association with microbial dechlorination increased significantly the performances of nanoscale iron. This is likely due to the synergistic effect between the two processes. Millimetric iron was always used in association with source zone containment; therefore, it is not possible to distinguish the contributions of the two techniques. The comparison also shows that catalyst addition seems to not dramatically improve treatment efficiency and that such improvement is not statistically significant. Finally, the injection technology is correlated to the type of iron and to the soil permeability.

A Comparison Between Field Applications of Nano-, Micro-, and Millimetric Zero-Valent Iron for the Remediation of Contaminated Aquifers / Comba, Silvia; DI MOLFETTA, Antonio; Sethi, Rajandrea. - In: WATER, AIR AND SOIL POLLUTION. - ISSN 1573-2932. - 215:(2011), pp. 595-607. [10.1007/s11270-010-0502-1]

A Comparison Between Field Applications of Nano-, Micro-, and Millimetric Zero-Valent Iron for the Remediation of Contaminated Aquifers

COMBA, SILVIA;DI MOLFETTA, Antonio;SETHI, RAJANDREA
2011

Abstract

In the last 10 years, the number of field applications of zero-valent iron differing from permeable reactive barrier has grown rapidly and at present are 112. This study analyzes and compares such field applications. By using statistical analysis, especially ANO VA and principal component analysis, this study shows that chlorinated solvent contamination can be treated efficiently by using zero-valent iron material singly or associated with other technologies. In the analyzed sample of case studies, the association with microbial dechlorination increased significantly the performances of nanoscale iron. This is likely due to the synergistic effect between the two processes. Millimetric iron was always used in association with source zone containment; therefore, it is not possible to distinguish the contributions of the two techniques. The comparison also shows that catalyst addition seems to not dramatically improve treatment efficiency and that such improvement is not statistically significant. Finally, the injection technology is correlated to the type of iron and to the soil permeability.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2372649
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo