The adoption of phase change materials (PCMs) in glazing can represent a way of improving the low thermal inertia of transparent envelope components. PCM allows the internal surface temperatures of the glazing to be controlled, and this could improve the energy efficiency and thermal comfort performance of a facade. In the present work, a prototype of a simple PCM glazing system is proposed and its behaviour is compared with that of a conventional reference double glazed unit. The surface temperatures and the transmitted irradiances of the PCM glazing prototype and of a reference fenestration, measured over a six-month experimental campaign, have been used to numerically evaluate the indoor thermal conditions inside a typical office room. Different boundary conditions, ranging from summer to winter season, including the mid-season, have been analysed. The results concerning thermal comfort are illustrated and discussed in this work and the glazing prototype, the experimental set-up and the measurement methods are presented. The obtained results demonstrate the promising performance of the PCM glaizing system, which is able to contribute to the attainment of a better indoor thermal environment.

Improving thermal comfort conditions by means of PCM glazing systems / Goia, Francesco; Perino, Marco; Serra, Valentina. - In: ENERGY AND BUILDINGS. - ISSN 0378-7788. - STAMPA. - 60:maggio 2013(2013), pp. 442-452. [10.1016/j.enbuild.2013.01.029]

Improving thermal comfort conditions by means of PCM glazing systems

GOIA, FRANCESCO;PERINO, Marco;SERRA, VALENTINA
2013

Abstract

The adoption of phase change materials (PCMs) in glazing can represent a way of improving the low thermal inertia of transparent envelope components. PCM allows the internal surface temperatures of the glazing to be controlled, and this could improve the energy efficiency and thermal comfort performance of a facade. In the present work, a prototype of a simple PCM glazing system is proposed and its behaviour is compared with that of a conventional reference double glazed unit. The surface temperatures and the transmitted irradiances of the PCM glazing prototype and of a reference fenestration, measured over a six-month experimental campaign, have been used to numerically evaluate the indoor thermal conditions inside a typical office room. Different boundary conditions, ranging from summer to winter season, including the mid-season, have been analysed. The results concerning thermal comfort are illustrated and discussed in this work and the glazing prototype, the experimental set-up and the measurement methods are presented. The obtained results demonstrate the promising performance of the PCM glaizing system, which is able to contribute to the attainment of a better indoor thermal environment.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2506224
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo