In this paper an example of a “nearly-zero-energy building” in northern Italy is presented. A critical analysis of the technologies design, both for increasing energy efficiency and renewable energy production is carried out. The available data from an energy monitoring campaign during the seasons 2010-2011 and 2011-2012 are presented and discussed in order to evaluate the real energy performance of the building. The data of the monitoring campaign are also used to assess the real operational conditions of the building in order to perform a tailored energy calculation. Thus the calculation is performed using both monthly quasi-steady-state method and an hourly dynamic model. The simulation results are compared with the real building energy monitored data to get a “validation” of the model.

Design and verification of a Zero Energy Building: evaluation of real energy performance and comparison with a tailored calculation / Capozzoli, Alfonso; Berra, L.; Russo, R.; Corrado, Vincenzo. - STAMPA. - (2013), pp. 495-503. (Intervento presentato al convegno VII Mediterranean Congress of Climatization (Climamed ’13) tenutosi a Istanbul nel 3-4 October, 2013).

Design and verification of a Zero Energy Building: evaluation of real energy performance and comparison with a tailored calculation

CAPOZZOLI, ALFONSO;CORRADO, Vincenzo
2013

Abstract

In this paper an example of a “nearly-zero-energy building” in northern Italy is presented. A critical analysis of the technologies design, both for increasing energy efficiency and renewable energy production is carried out. The available data from an energy monitoring campaign during the seasons 2010-2011 and 2011-2012 are presented and discussed in order to evaluate the real energy performance of the building. The data of the monitoring campaign are also used to assess the real operational conditions of the building in order to perform a tailored energy calculation. Thus the calculation is performed using both monthly quasi-steady-state method and an hourly dynamic model. The simulation results are compared with the real building energy monitored data to get a “validation” of the model.
2013
9789756907177
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2517089
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo