The application field of shield tunneling has extended in recent years. Most shield-driven tunnels are supported by segmental concrete linings. Although many well documented experimental, numerical and analytical results exist in literature concerning the functioning of segmental tunnel linings, their behavior under the influence of joints is still not clear. This paper presents a numerical study that has been performed to investigate the factors that affect segmental tunnel lining behavior. Analyses have been carried out using a two-dimensional finite difference element model. The longitudinal joint between segments in a ring has been simulated through double node connections, with six degrees of freedom, represented by six springs. The proposed model allows the effect of not only the rotational stiffness but also the radial stiffness and the axial stiffness of the longitudinal joints to be taken into consideration. The numerical results show a significant reduction in the bending moment induced in the tunnel lining as the joint number increases. The tunnel behavior in terms of the bending moment considering the effect of joint distribution, when the lateral earth pressure factor K0 is equal to 0.5, 1.5 and 2, is almost similar and differs when K0 is equal to unity. It has been seen that the influence of joint rotational stiffness, the reduction in joint rotation stiffness under the negative bending moment, the lateral earth pressure factor and Young’s modulus of ground surrounding the tunnel should not be neglected. On the other hand, the results have also shown an insignificant influence of the axial and radial stiffness of the joints on segmental tunnel lining behavior.

2D numerical investigation of segmental tunnel lining behavior / Do, N. A.; Dias, D.; Oreste, Pierpaolo; Djeran Maigre, I.. - In: TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY. - ISSN 0886-7798. - STAMPA. - 37:(2013), pp. 115-127. [10.1016/j.tust.2013.03.008]

2D numerical investigation of segmental tunnel lining behavior

ORESTE, PIERPAOLO;
2013

Abstract

The application field of shield tunneling has extended in recent years. Most shield-driven tunnels are supported by segmental concrete linings. Although many well documented experimental, numerical and analytical results exist in literature concerning the functioning of segmental tunnel linings, their behavior under the influence of joints is still not clear. This paper presents a numerical study that has been performed to investigate the factors that affect segmental tunnel lining behavior. Analyses have been carried out using a two-dimensional finite difference element model. The longitudinal joint between segments in a ring has been simulated through double node connections, with six degrees of freedom, represented by six springs. The proposed model allows the effect of not only the rotational stiffness but also the radial stiffness and the axial stiffness of the longitudinal joints to be taken into consideration. The numerical results show a significant reduction in the bending moment induced in the tunnel lining as the joint number increases. The tunnel behavior in terms of the bending moment considering the effect of joint distribution, when the lateral earth pressure factor K0 is equal to 0.5, 1.5 and 2, is almost similar and differs when K0 is equal to unity. It has been seen that the influence of joint rotational stiffness, the reduction in joint rotation stiffness under the negative bending moment, the lateral earth pressure factor and Young’s modulus of ground surrounding the tunnel should not be neglected. On the other hand, the results have also shown an insignificant influence of the axial and radial stiffness of the joints on segmental tunnel lining behavior.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2517724
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo