Data Elaboration Centers are characterized by high specific energy consumptions, due to the requirements for the working environment of IT machines and their large working loads. This is due to the fact that the control of the indoor air parameters is of paramount importance in order to maintain the servers in safe working conditions. Reliable diagnostic procedures are therefore needed. The work herewith presented proposes an innovative diagnostic method, which makes use of infrared thermal imaging for real-time monitoring of the air temperature field in the proximity to the server air inlet. The method is validated by means of an experimental assessment, with the aim to assess the capability of an industrial infrared camera to evaluate the air temperature field next to the inlet surface of the server racks, in real working conditions. Potential and limitations of this procedure are presented and discussed.

Temperature field real-time diagnosis by means of infrared imaging in Data Elaboration Center / Favoino, F.; Capozzoli, Alfonso; Perino, Marco. - STAMPA. - 3:(2013), pp. 455-463. (Intervento presentato al convegno 8th International Symposium on Heating, Ventilation and Air Conditioning tenutosi a XI'an (China) University of Architecture and Technology nel 19-21 October 2013) [10.1007/978-3-642-39578-9_48].

Temperature field real-time diagnosis by means of infrared imaging in Data Elaboration Center

Favoino F.;CAPOZZOLI, ALFONSO;PERINO, Marco
2013

Abstract

Data Elaboration Centers are characterized by high specific energy consumptions, due to the requirements for the working environment of IT machines and their large working loads. This is due to the fact that the control of the indoor air parameters is of paramount importance in order to maintain the servers in safe working conditions. Reliable diagnostic procedures are therefore needed. The work herewith presented proposes an innovative diagnostic method, which makes use of infrared thermal imaging for real-time monitoring of the air temperature field in the proximity to the server air inlet. The method is validated by means of an experimental assessment, with the aim to assess the capability of an industrial infrared camera to evaluate the air temperature field next to the inlet surface of the server racks, in real working conditions. Potential and limitations of this procedure are presented and discussed.
2013
9783642395772
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2518544
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo