Periodontal probing aims at detecting the presence, type and gravity of periodontal diseases influencing distance between gingival margin and connective ligament. Measurements in vivo are affected by substantial uncertainty, owing, for example, to probe features, anatomic variations and operator’s skill. Inadequate reproducibility in periodontal probing may lead to diagnostic mistakes and inappropriate therapeutic decisions. In vitro evaluation of reproducibility of measurements of periodontal pockets was aimed at while developing a Periodontal Calibration Box designed to calibrate periodontal probe operators, catering also for simulating contraction observed in vivo. Probe type and clinical experience of operators were found to affect substantially probing errors.

Probing depth in periodontal pockets: In vitro evaluation of contributions to variability due to probe type and operator skill / Erriu, Matteo; Genta, Gianfranco; Pili, Francesca Maria Giovanna; Barbato, Giulio; Denotti, Gloria; Levi, Raffaello. - In: PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS. PART H, JOURNAL OF ENGINEERING IN MEDICINE. - ISSN 0954-4119. - STAMPA. - 229:10(2015), pp. 743-749. [10.1177/0954411915606170]

Probing depth in periodontal pockets: In vitro evaluation of contributions to variability due to probe type and operator skill

GENTA, GIANFRANCO;BARBATO, Giulio;LEVI, Raffaello
2015

Abstract

Periodontal probing aims at detecting the presence, type and gravity of periodontal diseases influencing distance between gingival margin and connective ligament. Measurements in vivo are affected by substantial uncertainty, owing, for example, to probe features, anatomic variations and operator’s skill. Inadequate reproducibility in periodontal probing may lead to diagnostic mistakes and inappropriate therapeutic decisions. In vitro evaluation of reproducibility of measurements of periodontal pockets was aimed at while developing a Periodontal Calibration Box designed to calibrate periodontal probe operators, catering also for simulating contraction observed in vivo. Probe type and clinical experience of operators were found to affect substantially probing errors.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2620092
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo