In this paper, we have investigated the redundancy in array of Memristive-Biosensors and find optimum number for devices to accomplish reliable biodetection. Our results lead less expensive sensor and reduce the low-reproducibility of this memristive method for the detection of rabbit antigen. Several experiments have been performed with 17 memristive biosensors in several conditions. These conditions give us relevant informations about the overall behavior of memristor biosensor's array, after functionalization with antibody and exposure to antigen. The statistics made on different conditions, related to the standard deviation and the mean value of voltage gap, prove that such a sensor, with a minimum memristive biosensors in array, can be counted as reliable sensor for the detection of antigen.

Reliable redundancy with memristive-biosensors to achieve statistical significance in immunosensing / Lotfi, A.; Demarchi, Danilo; Puppo, F.; De Micheli, G.; Carrara, S.; Doucey, M. A.. - ELETTRONICO. - (2015), pp. 31-36. (Intervento presentato al convegno 2015 6th IEEE International Workshop on Advances in Sensors and Interfaces, IWASI 2015 tenutosi a Gallipoli, Italy nel 18-19 June 2015) [10.1109/IWASI.2015.7184969].

Reliable redundancy with memristive-biosensors to achieve statistical significance in immunosensing

DEMARCHI, DANILO;
2015

Abstract

In this paper, we have investigated the redundancy in array of Memristive-Biosensors and find optimum number for devices to accomplish reliable biodetection. Our results lead less expensive sensor and reduce the low-reproducibility of this memristive method for the detection of rabbit antigen. Several experiments have been performed with 17 memristive biosensors in several conditions. These conditions give us relevant informations about the overall behavior of memristor biosensor's array, after functionalization with antibody and exposure to antigen. The statistics made on different conditions, related to the standard deviation and the mean value of voltage gap, prove that such a sensor, with a minimum memristive biosensors in array, can be counted as reliable sensor for the detection of antigen.
2015
9781479989805
9781479989805
File in questo prodotto:
File Dimensione Formato  
07184969.pdf

non disponibili

Descrizione: Lotfi IWASI2016
Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 817.62 kB
Formato Adobe PDF
817.62 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2646248
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo