In the last few years opaque ventilated façades (OVFs) have reached an increasing diffusion in the Mediterranean area for their capability of reducing the heat flux across the building envelope in summer conditions as well as preventing the condensation and infiltration risk in the winter period providing wind and rain protection, thus increasing the durability of the façade. Moreover, the possibility to host different cladding allows architects to explore a wide range of façade combinations. In the framework of a regional funded project, an extensive in-field experimental campaign was carried out in the summer period on different full-scale OVF configurations, with the aim of assessing the thermal performance of a newly developed OVF based on hollow clay claddings technology. A sensitivity analysis was thus performed, in order to evaluate, on the one hand, the effect on the performance of the main façade features, e.g. ventilation channel height, solar absorption coefficient and ventilation grills openings ratio, and on the other hand, the influence of the outdoor boundary conditions, e.g. solar radiation and external air temperature. The experimental results highlight that the façade configuration and the design features significantly affect the capability of OVFs on minimising the solar heat loads across the wall (between ~30% and ~70%) if compared to an unventilated façade (representing the reference configuration). These results allow providing general guidelines for an optimised OVF design. Moreover, the assessment of the effect of the outdoor boundary conditions allowed to identify the conditions in which the façade shows the higher exploitation of natural ventilation.

Knowledge Searching, Integrating and Performing: Always a Tuned Trio for Innovation? / Neirotti, Paolo; Martini, A.; Appio, F. P.. - In: LONG RANGE PLANNING. - ISSN 0024-6301. - 50:2(2017), pp. 200-220. [10.1016/j.lrp.2015.12.020]

Knowledge Searching, Integrating and Performing: Always a Tuned Trio for Innovation?

NEIROTTI, Paolo;
2017

Abstract

In the last few years opaque ventilated façades (OVFs) have reached an increasing diffusion in the Mediterranean area for their capability of reducing the heat flux across the building envelope in summer conditions as well as preventing the condensation and infiltration risk in the winter period providing wind and rain protection, thus increasing the durability of the façade. Moreover, the possibility to host different cladding allows architects to explore a wide range of façade combinations. In the framework of a regional funded project, an extensive in-field experimental campaign was carried out in the summer period on different full-scale OVF configurations, with the aim of assessing the thermal performance of a newly developed OVF based on hollow clay claddings technology. A sensitivity analysis was thus performed, in order to evaluate, on the one hand, the effect on the performance of the main façade features, e.g. ventilation channel height, solar absorption coefficient and ventilation grills openings ratio, and on the other hand, the influence of the outdoor boundary conditions, e.g. solar radiation and external air temperature. The experimental results highlight that the façade configuration and the design features significantly affect the capability of OVFs on minimising the solar heat loads across the wall (between ~30% and ~70%) if compared to an unventilated façade (representing the reference configuration). These results allow providing general guidelines for an optimised OVF design. Moreover, the assessment of the effect of the outdoor boundary conditions allowed to identify the conditions in which the façade shows the higher exploitation of natural ventilation.
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0024630115000965-main.pdf

non disponibili

Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 618.36 kB
Formato Adobe PDF
618.36 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2647689
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo