In this work mass transfer in liquid–liquid extraction is investigated with the two-dimensional high-order moment-conserving method of classes (2D-HMMC) (Buffo and Alopaeus, 2016). The solution of a realistic liquid–liquid test case, a counter-current rotating disc column (RDC) composed of three stages where the droplets exchange mass with the continuous phase, is studied. This detailed modelling approach is compared with two other possible approximated models. In the first all the droplets are assumed to have the same size and concentration, and in the second all the droplets are assumed to have the same concentration but different sizes. The results of this comparison show that the information regarding the two-dimensional droplet size-concentration distribution may be needed to properly evaluate the mass transfer rates and therefore the behaviour of the system for all the operating conditions investigated.

Liquid–liquid extraction in a rotating disc column: Solution of 2D population balance with HMMC / Buffo, Antonio; Jama, M.; Alopaeus, V.. - In: CHEMICAL ENGINEERING RESEARCH & DESIGN. - ISSN 0263-8762. - ELETTRONICO. - 115:(2016), pp. 270-281. [10.1016/j.cherd.2016.09.002]

Liquid–liquid extraction in a rotating disc column: Solution of 2D population balance with HMMC

BUFFO, ANTONIO;
2016

Abstract

In this work mass transfer in liquid–liquid extraction is investigated with the two-dimensional high-order moment-conserving method of classes (2D-HMMC) (Buffo and Alopaeus, 2016). The solution of a realistic liquid–liquid test case, a counter-current rotating disc column (RDC) composed of three stages where the droplets exchange mass with the continuous phase, is studied. This detailed modelling approach is compared with two other possible approximated models. In the first all the droplets are assumed to have the same size and concentration, and in the second all the droplets are assumed to have the same concentration but different sizes. The results of this comparison show that the information regarding the two-dimensional droplet size-concentration distribution may be needed to properly evaluate the mass transfer rates and therefore the behaviour of the system for all the operating conditions investigated.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2663549
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo