The energy-related products Directive (ErP) 2009/125/EC has set a new generation of equipment that are more energy efficient and reliable. In the case of climate control for livestock housing, a key role can be played by \EC\ motors direct drive variable flow fans that can be used instead of traditional \AC\ fans in applications like broiler or dairy houses. The energy consumptions of such fans strictly depend on the specific application and on the outdoor weather conditions, and there is therefore the need to forecast their energy performance by means of computational tools. In this work, we present a tool developed by the Authors and based on a dynamic model for the estimation of the global (electricity, natural gas, etc.) annual energy consumption of a system installed into an animal house. The calculation is based on a customization of the \ISO\ 13790 Standard simplified hourly model for the energy performance assessment of broiler houses.
Energy performance and indoor environmental control of animal houses: A modelling tool / Fabrizio, Enrico; Ghiggini, Andrea; Bariani, Mauro. - In: ENERGY PROCEDIA. - ISSN 1876-6102. - 82:(2015), pp. 439-444. [10.1016/j.egypro.2015.11.833]
Energy performance and indoor environmental control of animal houses: A modelling tool
FABRIZIO, ENRICO;
2015
Abstract
The energy-related products Directive (ErP) 2009/125/EC has set a new generation of equipment that are more energy efficient and reliable. In the case of climate control for livestock housing, a key role can be played by \EC\ motors direct drive variable flow fans that can be used instead of traditional \AC\ fans in applications like broiler or dairy houses. The energy consumptions of such fans strictly depend on the specific application and on the outdoor weather conditions, and there is therefore the need to forecast their energy performance by means of computational tools. In this work, we present a tool developed by the Authors and based on a dynamic model for the estimation of the global (electricity, natural gas, etc.) annual energy consumption of a system installed into an animal house. The calculation is based on a customization of the \ISO\ 13790 Standard simplified hourly model for the energy performance assessment of broiler houses.File | Dimensione | Formato | |
---|---|---|---|
1-s2.0-S187661021502593X-main.pdf
accesso aperto
Descrizione: EGYPRO_M
Tipologia:
2. Post-print / Author's Accepted Manuscript
Licenza:
Creative commons
Dimensione
340.48 kB
Formato
Adobe PDF
|
340.48 kB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2668115
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo