We analyze the power-delay trade-off in a Network-on-Chip (NoC) under three Dynamic Voltage and Frequency Scaling (DVFS) policies. The first rate-based policy sets frequency and voltage of the NoC to the minimum value that allows to sustain the injection rate without reaching saturation. The second queue-based policy uses a feedback-loop approach to throttle the NoC frequency and voltage such that the average backlog of the injection queues tracks a target value. The third delay-based policy uses a closed- loop strategy that targets a given NoC end-to-end average delay. We first show that, despite the different mechanism and implementation, both rate-based and queue-based policies obtain very similar results in terms of power and delay, and we propose a theoretical interpretation of this similarity. Then, we show that delay-based policy generally offers a better power-delay trade-off. We obtained our results with an extensive set of experiments on synthetic traffic, as well as multimedia, communications and PARSEC benchmarks. For all the experiments, we report both cycle-accurate simulation results for the analysis of NoC delay and accurate power results obtained targeting a standard-cell library in an advanced 28-nm FDSOI CMOS technology.

Power-performance assessment of different DVFS control policies in NoCs / Casu, MARIO ROBERTO; Giaccone, Paolo. - In: JOURNAL OF PARALLEL AND DISTRIBUTED COMPUTING. - ISSN 0743-7315. - STAMPA. - 109:(2017), pp. 193-207. [10.1016/j.jpdc.2017.06.004]

Power-performance assessment of different DVFS control policies in NoCs

CASU, MARIO ROBERTO;GIACCONE, PAOLO
2017

Abstract

We analyze the power-delay trade-off in a Network-on-Chip (NoC) under three Dynamic Voltage and Frequency Scaling (DVFS) policies. The first rate-based policy sets frequency and voltage of the NoC to the minimum value that allows to sustain the injection rate without reaching saturation. The second queue-based policy uses a feedback-loop approach to throttle the NoC frequency and voltage such that the average backlog of the injection queues tracks a target value. The third delay-based policy uses a closed- loop strategy that targets a given NoC end-to-end average delay. We first show that, despite the different mechanism and implementation, both rate-based and queue-based policies obtain very similar results in terms of power and delay, and we propose a theoretical interpretation of this similarity. Then, we show that delay-based policy generally offers a better power-delay trade-off. We obtained our results with an extensive set of experiments on synthetic traffic, as well as multimedia, communications and PARSEC benchmarks. For all the experiments, we report both cycle-accurate simulation results for the analysis of NoC delay and accurate power results obtained targeting a standard-cell library in an advanced 28-nm FDSOI CMOS technology.
File in questo prodotto:
File Dimensione Formato  
jpdc.pdf

Open Access dal 22/06/2019

Descrizione: Camera ready
Tipologia: 2. Post-print / Author's Accepted Manuscript
Licenza: Creative commons
Dimensione 763.87 kB
Formato Adobe PDF
763.87 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2675947
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo