Nuclepore filters are capillary pore membrane filters with an array of microscopic cylindrical holes of uniform diameters. Their structure is suitable for particle collection and ensuing offline analyses, therefore they are being widely used for exposure assessment of engineered nanoparticles, ambient PM2.5, virus, bacteria, asbestos, etc., as well as in powder manufacturing industries. However, there exists a particle size range in which all the filtration capture mechanisms are not effective. This size is the most penetrating particle size (MPPS), which corresponds to the minimum efficiency (ME) of the filter. Both MPPS and ME are important parameters for a user to select an adequate Nuclepore filter and preferred operating conditions. For rapid estimation of the MPPS and ME, we derived their explicit expressions by simplifying the formulas for the impaction, diffusion and interception deposition and differentiating the combined efficiency with respect to the particle size. The comparison between the experimental data and the prediction from the explicit expressions shows the explicit expressions can provide MPPS for a wide range of filter properties (pore radius, porosity and length) and filtration conditions (particle density, face velocity and temperature). The ME can also be estimated satisfactorily when a simplified term of filter surface diffusion deposition is further considered. By the explicit expressions of MPPS and ME, a quick screening for selecting a Nuclepore filter with the proper properties and suitable filtration conditions can be easily achieved. From the theoretical point of view, the explicit expressions facilitate better understanding of the effects of filter properties and conditions on the filtration characteristics

Explicit expressions for the minimum efficiency and most penetrating particle size of Nuclepore filters / Hu, Y.; Chen, S. C.; Tronville, PAOLO MARIA; Pui, D. Y. H.; Wang, J.. - STAMPA. - (2016), pp. 168-168. (Intervento presentato al convegno WFC 12 - 12th World Filtration Congress tenutosi a Taipei (Taiwan) nel 11-15 April 2016).

Explicit expressions for the minimum efficiency and most penetrating particle size of Nuclepore filters

TRONVILLE, PAOLO MARIA;
2016

Abstract

Nuclepore filters are capillary pore membrane filters with an array of microscopic cylindrical holes of uniform diameters. Their structure is suitable for particle collection and ensuing offline analyses, therefore they are being widely used for exposure assessment of engineered nanoparticles, ambient PM2.5, virus, bacteria, asbestos, etc., as well as in powder manufacturing industries. However, there exists a particle size range in which all the filtration capture mechanisms are not effective. This size is the most penetrating particle size (MPPS), which corresponds to the minimum efficiency (ME) of the filter. Both MPPS and ME are important parameters for a user to select an adequate Nuclepore filter and preferred operating conditions. For rapid estimation of the MPPS and ME, we derived their explicit expressions by simplifying the formulas for the impaction, diffusion and interception deposition and differentiating the combined efficiency with respect to the particle size. The comparison between the experimental data and the prediction from the explicit expressions shows the explicit expressions can provide MPPS for a wide range of filter properties (pore radius, porosity and length) and filtration conditions (particle density, face velocity and temperature). The ME can also be estimated satisfactorily when a simplified term of filter surface diffusion deposition is further considered. By the explicit expressions of MPPS and ME, a quick screening for selecting a Nuclepore filter with the proper properties and suitable filtration conditions can be easily achieved. From the theoretical point of view, the explicit expressions facilitate better understanding of the effects of filter properties and conditions on the filtration characteristics
File in questo prodotto:
File Dimensione Formato  
WFC 12 Scientific Program.pdf

accesso aperto

Descrizione: Programma scientifico del congresso
Tipologia: Altro materiale allegato
Licenza: PUBBLICO - Tutti i diritti riservati
Dimensione 6.48 MB
Formato Adobe PDF
6.48 MB Adobe PDF Visualizza/Apri
PM-19.pdf

accesso aperto

Descrizione: Abstract pubblicato negli atti digitali del congresso
Tipologia: Abstract
Licenza: PUBBLICO - Tutti i diritti riservati
Dimensione 10.47 kB
Formato Adobe PDF
10.47 kB Adobe PDF Visualizza/Apri
P19_AbstractPrint.pdf

accesso aperto

Descrizione: abs
Tipologia: Abstract
Licenza: PUBBLICO - Tutti i diritti riservati
Dimensione 129.1 kB
Formato Adobe PDF
129.1 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2675982
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo