In magnetic resonance imaging (MRI), gradient coils are switched during fast current pulse sequences. These time-varying fields interact with the conducting structures of the scanner, producing deleterious effects such as image distortions and Joule heating. Using a multi-layer integral method, the spatiotemporal nature of the eddy currents induced by the gradient coils is investigated. The existence of the eigenmode is experimentally demonstrated by measuring the magnetic field and the time decay constant of a typical unshielded z-gradient coil and its interaction with a conductive cylinder. An effective current tailoring is achieved using the characteristic eigenvalues of the conducting domain-exciting coil system. The method can be used to understand and mitigate undesired effects of eddy currents in MRI.

Modal Analysis of Currents Induced by Magnetic Resonance Imaging Gradient Coils / Hector, Sanchez; Michael, Poole; Adnan, Trakic; Freschi, Fabio; Elliot, Smith; Jeremy, Herbert; Miguel, Fuentes; Yu, Li; Fangfang, Tang; Repetto, Maurizio; Stuart, Crozier. - In: IEEE TRANSACTIONS ON MAGNETICS. - ISSN 0018-9464. - 50:2(2014), pp. 945-948. [10.1109/TMAG.2013.2282392]

Modal Analysis of Currents Induced by Magnetic Resonance Imaging Gradient Coils

FRESCHI, FABIO;REPETTO, MAURIZIO;
2014

Abstract

In magnetic resonance imaging (MRI), gradient coils are switched during fast current pulse sequences. These time-varying fields interact with the conducting structures of the scanner, producing deleterious effects such as image distortions and Joule heating. Using a multi-layer integral method, the spatiotemporal nature of the eddy currents induced by the gradient coils is investigated. The existence of the eigenmode is experimentally demonstrated by measuring the magnetic field and the time decay constant of a typical unshielded z-gradient coil and its interaction with a conductive cylinder. An effective current tailoring is achieved using the characteristic eigenvalues of the conducting domain-exciting coil system. The method can be used to understand and mitigate undesired effects of eddy currents in MRI.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2543359
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo