The design of a pump and treat (P&T) system for the hydraulic control of a contaminated plume in a confined aquifer is presented here. Being the system designed for the emergency containment of a nonaqueous phase liquid plume, the evaluation of the system’s short-term efficiency was considered an important issue. For this reason, both time-related and ultimate capture zones were defined. They were traced using the automatic protection area (APA) model, a capture-zone delineation tool based on a hybrid forward-backward particle tracking algorithm, that provides an automatic post-processing encirclement of capture zones. Two simple indexes are here proposed for the evaluation of the performance of the hydraulic barrier, that is, the efficacy and efficiency indexes, calculated from the capture areas provided by APA. The discharge rates of the wells were dimensioned applying the APA algorithm, maximizing efficacy and efficiency of the barrier. Results proved both visually (via plotting of capture zones) and numerically (via calculation of the indexes) that the P&T system can provide a complete capture of the contaminated area and minimizes the volume of extracted water. Consequently, the APA algorithm was proved to be a useful tool in capture zone delineation. As a future perspective, it could be coupled with the real-time measurement of pumping rates and water levels and be implemented as a part of a tuning tool for the management of the hydraulic barrier.

Automatic delineation of capture zones for pump and treat systems: A case study in piedmont, Italy / Tosco, TIZIANA ANNA ELISABETTA; DI MOLFETTA, Antonio; Sethi, Rajandrea. - In: GROUND WATER MONITORING AND REMEDIATION. - ISSN 1069-3629. - STAMPA. - 30(2):(2010), pp. 46-52. [10.1111/j.1745-6592.2010.01276.x]

Automatic delineation of capture zones for pump and treat systems: A case study in piedmont, Italy

TOSCO, TIZIANA ANNA ELISABETTA;DI MOLFETTA, Antonio;SETHI, RAJANDREA
2010

Abstract

The design of a pump and treat (P&T) system for the hydraulic control of a contaminated plume in a confined aquifer is presented here. Being the system designed for the emergency containment of a nonaqueous phase liquid plume, the evaluation of the system’s short-term efficiency was considered an important issue. For this reason, both time-related and ultimate capture zones were defined. They were traced using the automatic protection area (APA) model, a capture-zone delineation tool based on a hybrid forward-backward particle tracking algorithm, that provides an automatic post-processing encirclement of capture zones. Two simple indexes are here proposed for the evaluation of the performance of the hydraulic barrier, that is, the efficacy and efficiency indexes, calculated from the capture areas provided by APA. The discharge rates of the wells were dimensioned applying the APA algorithm, maximizing efficacy and efficiency of the barrier. Results proved both visually (via plotting of capture zones) and numerically (via calculation of the indexes) that the P&T system can provide a complete capture of the contaminated area and minimizes the volume of extracted water. Consequently, the APA algorithm was proved to be a useful tool in capture zone delineation. As a future perspective, it could be coupled with the real-time measurement of pumping rates and water levels and be implemented as a part of a tuning tool for the management of the hydraulic barrier.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2372619
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo