The first step of the validation of the recently developed thermal-hydraulic code 4C is presented. We study the transient evolution during a so-called standard 25 kA safety discharge of the International Thermonuclear Experimental Reactor (ITER) Toroidal Field Model Coil (TFMC), tested in 2001–2002 in the TOSKA facility at the Karlsruhe Institute of Technology, Germany. The computed outlet He temperatures from both winding and case cooling channels, as well as the local maximum temperature increase of the structures, are shown to be in good agreement with the measured data.

Validation of the 4C Thermal-Hydraulic Code against 25 kA Safety Discharge in the ITERToroidal Field Model Coil (TFMC) / Zanino, Roberto; Bonifetto, Roberto; Heller, R.; Savoldi, Laura. - In: IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY. - ISSN 1051-8223. - STAMPA. - 21:3(2011), pp. 1948-1952. [10.1109/TASC.2010.2089771]

Validation of the 4C Thermal-Hydraulic Code against 25 kA Safety Discharge in the ITERToroidal Field Model Coil (TFMC)

ZANINO, Roberto;BONIFETTO, ROBERTO;SAVOLDI, LAURA
2011

Abstract

The first step of the validation of the recently developed thermal-hydraulic code 4C is presented. We study the transient evolution during a so-called standard 25 kA safety discharge of the International Thermonuclear Experimental Reactor (ITER) Toroidal Field Model Coil (TFMC), tested in 2001–2002 in the TOSKA facility at the Karlsruhe Institute of Technology, Germany. The computed outlet He temperatures from both winding and case cooling channels, as well as the local maximum temperature increase of the structures, are shown to be in good agreement with the measured data.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2375502
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo