Masonry infills panels placed among framed structures meshes have a relevant influence in presence seismic actions in terms of strength stiffness and global displacement capacity. In the case of RC structures, the modifications of internal forces due to infill-frame interaction may be not compatible with surrounding frame members strength especially considering additional shear forces arising at the ends of beams and columns in contact with the panel under lateral actions. Such effects may be in many cases the cause of unexpected brittle collapse mechanisms which compromise the safety of the entire structure. In this paper by means of a double (micromodeling and macromodeling) procedure regarding RC meshes infilled with hollow brick masonry, a parametric study is provided defining a connection between local shear forces in critical frame regions and axial force on diagonal pin jointed strut. Proposed strategy allows to predict effective local shear forces using the simple macromodeling approach to reproduce the effect of masonry infills in models.

Analysis of local shear effects in brick masonry infilled RC frames / Cavaleri, L.; DI TRAPANI, Fabio; Papia, M.. - ELETTRONICO. - (2013), pp. 2962-2977. (Intervento presentato al convegno 4th International Conference on Computational Methods in Structural Dynamics and Earthquake Engineering, COMPDYN 2013 tenutosi a Kos Island, grecia nel 2013).

Analysis of local shear effects in brick masonry infilled RC frames

DI TRAPANI, FABIO;
2013

Abstract

Masonry infills panels placed among framed structures meshes have a relevant influence in presence seismic actions in terms of strength stiffness and global displacement capacity. In the case of RC structures, the modifications of internal forces due to infill-frame interaction may be not compatible with surrounding frame members strength especially considering additional shear forces arising at the ends of beams and columns in contact with the panel under lateral actions. Such effects may be in many cases the cause of unexpected brittle collapse mechanisms which compromise the safety of the entire structure. In this paper by means of a double (micromodeling and macromodeling) procedure regarding RC meshes infilled with hollow brick masonry, a parametric study is provided defining a connection between local shear forces in critical frame regions and axial force on diagonal pin jointed strut. Proposed strategy allows to predict effective local shear forces using the simple macromodeling approach to reproduce the effect of masonry infills in models.
2013
978-960-99994-2-7
File in questo prodotto:
File Dimensione Formato  
COMPDYN 2013_FULL_PAPER_CAVALERI_ DI TRAPANI_PAPIA.pdf

accesso aperto

Descrizione: articolo principale
Tipologia: 2. Post-print / Author's Accepted Manuscript
Licenza: PUBBLICO - Tutti i diritti riservati
Dimensione 748.55 kB
Formato Adobe PDF
748.55 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2671999
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo